XIMEA Camera Device¶
Available on macOS
Description¶
Interface to a XIMEA camera.
MWorks configures the camera to capture 8-bit, grayscale images. Each frame capture is triggered by MWorks (i.e. software triggering). In addition, the output pin on the camera (OUT1 if there are multiple outputs) is configured to be on during frame exposure.
Multiple cameras can be connected and used simultaneously, as long as serial_number is specified for each device.
Signature¶
iodevice/ximea_camera
Required Parameters¶
exposure_time¶
- Example
2ms
Exposure time for each captured frame. Must be greater than zero.
capture_interval¶
- Example
33.33ms
Interval between frame captures. Must be greater than zero.
image_data¶
Variable in which to store captured frames.
The value assigned to the variable is a binary string containing a JPEG-encoded image. The time stamp of the assignment is taken immediately after MWorks triggers the frame capture.
Optional Parameters¶
serial_number¶
- Example
12345678
Serial number of the desired camera.
If only one camera is connected, this parameter can be omitted, and MWorks will connect to the one available device.
autostart¶
- Default
NO
If YES
, the device will start I/O automatically (as if by an
implicit Start IO Device action) when the experiment starts running.
Note: Device I/O will always stop automatically when the experiment stops running, irrespective of this setting.
alt¶
Alternative device to use if this one fails to initialize (e.g. because the required hardware is not available). If #allowAltFailover
is set to 0 or false, this parameter is ignored.
Placement¶
Allowed at top level: |
Yes |
---|---|