ITC-18 Triggered Analog Snippet

Description

Used for recording an analog snippet on an ITC-18 IO Device. A TTL channel is used to trigger the snippet.

Signature

iochannel/itc18_triggered_analog_snippet

Required Parameters

variable

capability

Example:ITC18_ADC_INPUT0

data_type

Example:triggered_analog_snippet

direction

Example:output

synchrony

Example:hardware_timed_synchronous

range_min

Example:-10

range_max

Example:10

resolution

Example:16

update_interval

Example:3ms

data_interval

Example:70us

TTL_trigger_port

Example:0

pre_trigger_interval

Example:4ms

post_trigger_interval

Example:4ms